INSTALLATION
Collectramatic
®
Fryers – 8000 Series Control – OF49C & OF59C – A&W Food Services of Canada Inc.6
www.winstonind.com
800-234-5286
ELECTRIC
Refer to wiring circuit diagram (pages 31-33) for installation assistance. The
appliance is shipped wired for a 3-phase application. The 240 volt fryers may be
changed to single phase operation, as indicated in the chart below. A licensed
electrician may be required. Check local codes.
Following is a copy of the electrical information on the name plate for various
models of Winston’s Collectramatic
®
fryers.
Model Volts Hertz PH Amps Watts Circuit
Amp
OF49C 208 60 3 29.2 10,500 US/CAN 50
240 60 1 43.7 10,500 US/CAN 60
240 60 3 25.2 10,500 US/CAN 50
OF59C 208 60 3 29.2 10,500 US/CAN 50
240 60 1 43.7 10,500 US/CAN 60
240 60 3 25.2 10,500 US/CAN 50
SHIPPING DAMAGE
All equipment should be thoroughly examined for shipping damage before, during
and after unloading. It has been carefully inspected at our factory and the carrier
has assumed responsibility for its safe arrival. If the equipment is damaged,
either apparent or concealed, a claim must be made to the carrier.
APPARENT LOSS OR DAMAGE
If there is an obvious loss or damage, it must be noted on the freight bill or express
receipt and signed by the carrier’s agent; otherwise, the carrier may refuse the
claim. The carrier will supply the necessary forms.
CONCEALED LOSS OR DAMAGE
When loss or damage is not apparent until after the equipment is uncrated, a claim
for concealed damage must be made. Upon discovering damage, make a request in
writing to the carrier for inspection within 15 days, and retain all packing. The carrier
will supply an inspection report and the required claim forms.
PHYSICAL
Model Height with Width Depth Weight
Feet (IN/MM) (IN/MM) (IN/MM) (LBS/KG)
OF49C 45.5/1156 20.2/513 28.6/726 135/61
OF59C 45.5/1156 20.2/513 28.6/726 145/66
Comentários a estes Manuais